  • Test the lead wires using the 1) Lead wire Performance Test and 2) a 12L patient simulator to identify any shorted lead wires. Replace any lead wires that fail testing. Instructions for performing the Lead wire Performance Test are included in the Procedure section of this FCO, as well as in the TC Cardiograph Instructions for Use document included on the TC User Documentation DVD shipped with the cardiographs. A newly redesigned, more durable limb lead wire has recently been released. The new limb lead wire will be included in all TC70/50/30 cardiograph and TC replacement lead set shipments starting 15 July 2012. The precordial (chest) lead wires have not changed, nor have the replacement lead set part numbers. The new design limb lead wires are identified with date code “XD” or later molded in the location shown in Figure 1 below.

    Testen Sie die Anschlusskabel mit dem 1) Anschlusskabellänge Performance Test und 2) ein 12L Patienten-Simulator keine kurzgeschlossen Zuleitungen zu identifizieren. Ersetzen Sie alle Anschlussdrähte, die Tests fehlschlagen. Anweisungen zur Durchführung der Anschlusskabellänge Performance Test werden im Abschnitt 'Vorgehensweise dieser FCO, sowie in den TC Cardiograph Gebrauchsanweisung Dokument auf dem TC User Documentation DVD mit den Kardiographen ausgeliefert inklusive. Eine neu gestaltete, haltbarer Leib Zuleitung wurde vor kurzem veröffentlicht. Der neue Leib Anschlusskabel wird in allen TC70/50/30 Kardiographen und TC Ersatz Kabelset Sendungen ab 15. Juli 2012 aufgenommen werden. Die präkordialen (Brust) Anschlussdrähte haben sich nicht geändert, noch haben die Ersetzung Blei gesetzt Teilenummern. Das neue Design des Körpers Leitungsdrähte sind mit Datum Code "XD" identifiziert oder später in den in Abbildung 1 gezeigt geformt.

  • The QRS wave must be a minimum of 100μV peak to peak or greater for the lead’s complex to be measured. The operation of the cardiograph below this value may cause incorrect ECG analysis.

    Der QRS-Welle muss ein Minimum von 100μV peak to peak oder mehr für die Führung der komplexen gemessen werden kann. Der Betrieb des Kardiograph unterhalb dieses Wertes kann zu falschen EKG-Analyse.

  • Diagnostic Tests – used to identify and to troubleshoot a technical problem with the cardiograph and require a password to access

    Diagnostische Tests - zur Identifizierung und ein technisches Problem mit dem Kardiographen beheben und erfordern ein Kennwort für den Zugriff

  • Set the simulator to the 2Hz square wave setting and the amplitude to 1mV. 2 Ensure that the Simulated Waveform feature (cardiograph displays simulated patient ECG waveforms) is not enabled on the cardiograph. 3 Touch the Exam button on the Status Bar, and then touch the Resting 12-Lead button. 4 Touch the factory default Standard 12-lead Exam Profile button. 5 Touch the Settings button on the Status Bar. a Set the Artifact filter to OFF. b Set the Limb Leads setting to 10 mm/mV. c Set the Speed setting to 25 mm/sec. d Touch OK. 6 Touch the ECG button on the toolbar. If a message appears that no patient information has been entered, touch the Continue button. Depending on how the cardiograph is configured, the ECG may automatically print. If not, touch the Print button.

    Stellen Sie den Simulator an das 2Hz Rechtecksignal Einstellung und der Amplitude 1 mV. 2 Stellen Sie sicher, dass das simulierte Waveform-Funktion (cardiograph zeigt simulierten Patienten EKG-Kurven) nicht auf dem cardiograph aktiviert. 3 Berühren Sie die Prüfung auf der Statusleiste, und berühren Sie dann die Ruhe 12-Kanal-Taste. 4 Berühren Sie die werkseitigen Standard-12-Kanal-Exam Profil-Taste. 5 Berühren Sie die Schaltfläche Einstellungen auf der Statusleiste. a. Setzen Sie das Artefakt Filter auf OFF. b Legen Sie die Extremitätenableitungen Einstellung 10 mm / mV. c Stellen Sie die Speed-Einstellung auf 25 mm / sec. d Tippen Sie auf OK. 6 Berühren Sie die EKG-Symbolleiste auf die Schaltfläche. Wenn eine Meldung erscheint, dass keine Patientendaten eingegeben wurde, berühren Sie die Schaltfläche Weiter. Je nachdem wie die cardiograph konfiguriert ist, kann das EKG automatisch gedruckt. Wenn nicht, drücken Sie die Schaltfläche Drucken.