pressure reduction
Wörterbuch
-
pressure reduction
Beispiele im Kontext
-
an additional pressure reduction should be installed after valve 3
ein zusätzlicher Druckabfall sollte nach Ventil 3 installiert werden
-
Percentage of observations on pressure reduction surface, mean 7 SD
Prozentsatz der Beobachtungen über Druckreduktionsfläche, im Durchschnitt 7 SD
-
This exclusion does not apply to standard pressure equipment such as may be found in pressure reduction stations or compression stations;
Dieser Ausschluß erstreckt sich nicht auf Standarddruckgeräte, wie z. B. Druckgeräte, die sich in Druckregelstationen und in Kompressorstationen finden können;
-
In hemodynamic studies in patients with essential hypertension, blood pressure reduction was accompanied by a reduction in peripheral arterial resistance with an increase in cardiac output and little or no change in heart rate.
Bei Patienten mit essenzieller Hypertonie zeigten hämodynamische Studien, dass die Blutdrucksenkung mit einer Abnahme des peripheren arteriellen Widerstandes und einer Zunahme des Herzminutenvolumens einherging, die Herzfrequenz aber kaum verändert war.
-
Generically, ACEi reduce microalbuminuria in IDDM, to an extent that may not be fully accounted for by blood pressure reduction.
Generisch reduzieren ACE-Hemmer Mikroalbuminurie bei IDDM bis zu einem Punkt, der sich nicht vollständig durch die Blutdruckreduzierung erklären lässt.
-
Cross Line Relief Valves Main Relief Valve Pressure Reduction Valve Solenoid Valve
Cross Line-Sicherheitsventile Wichtigsten Überströmventil Druck Reduzierung Ventil Magnetventil
-
Cross Line Relief Valves Main Relief Valve Pressure Reduction Valve Solenoid Valve
Cross Line-Sicherheitsventile Wichtigsten Überströmventil Reduzierung Druckventil Magnetventil
-
The scenario here is overpressure of the propane gas system due to failure of the propane pressure reducing valve, PCV-27377, leading to loss of containment in the boiler house. In the Final Bow-Tie report credit is taken for protection against overpressure from PIZA-27372. There is however no high pressure trip, so this may have to be added by SKG. Our understanding of the system is as follows: The pressure reduction valve PCV-27377 is an RMG 300 Gas Pressure Regulator with an integral SAV (SAV-27377) set at ?? barg. The SAV vents to ??. Downstream of PCV-27377 is a SBV (SV-44702) safety relief valve for gas leakages which is set at 0.8 barg. This is not sized for the full flow through PCV-27377 and hence is not valid as a safety barrier. We would like to request SKG to explain the protection against overpressure of the propane (ignition) gas system.
Das Szenario ist hier Überdruck des Propangas-System wegen des Ausfalls der Propan-Druckreduzierventil, PCV-27.377, was zum Verlust des Containments im Kesselhaus. Im Final Bow-Tie Bericht Kredit wird zum Schutz vor Überdruck von PIZA-27.372 übernommen. Es gibt jedoch keine Hochdruck-Reise, so kann dies müssen von SKG hinzugefügt werden. Unser Verständnis des Systems ist wie folgt: Das Druckreduzierventil PCV-27377 ist ein RMG 300 Gas-Druckregelgerät mit integriertem SAV (SAV-27.377) eingestellt auf? barg. Die SAV Belüftungssystem?. Stromabwärts von PCV-27377 ist ein SBV (SV-44702) Sicherheitsventil für Gasleckagen, die bei 0,8 barg eingestellt ist. Dies ist nicht Größe für die volle Durchströmung PCV-27.377 und damit ist nicht gültig als Sicherheitsbarriere. Wir möchten Sie bitten SKG, den Schutz vor Überdruck des Propan (Zündung) Gasanlage erklären.